Basement Walls Negative Side Indoor Waterproofing
1- Concrete
2- Option 1: Surface preparation and application of Aquafin IC in 2 coats at a rate of 0.75 kg/m2 per coat
Do not paint or plaster or tile on top of Aquafin IC
Option 2: Surface preparation and application of Aquafin 1K in 4 coats at a rate of 1kg/m2 per coat